Technogips Pro W1-1
Certified system solutions. Guaranteed results.
Interior partition wall made of single metal stud frame and two-sided single-layer cladding of gypsum plasterboard.
Characteristics
Class of Fire Resistance | up to EI 60 |
Airborne Sound Insulation Rw | up to 57 dB |
Wall Self-Weight | up to 31 kg/m² |
Wall Thickness |
75 | 100 | 125 | 150 | 175 mm |
Wall Heights | up to 10.50 m |
Optimal moisture protection when done with:
- Gypsum plasterboard Type Н2;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board DFH1IR;
- Blue Board Type GM DFH1IR;
Optimal fire protection when done with:
- Gypsum plasterboard Type DF;
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High level of airborne sound insulation when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High impact resistance and exceptional strength when done with:
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
System components
1 | Board Technogips Pro Type A / H2 / DFIR / DFH2 / Sound Comfort Extra DFIR / Titan Board / Blue Board |
2 | Premium Profile CW 50, 75, 100, 125, 150 / 0.6 mm |
3 | Premium Profile UW 50, 75, 100, 125, 150 / 0.6 mm |
4 | Acoustic foam tape @ the peripheral profiles |
5 | Joint tape @ all last layers joints + peripheral ones |
6 |
Joint filler FUGA&FINISH Light / FUGA FUGA for fire protection @ all layers |
7.1 | Drywall screw 3.5 x 25 mm @ 250 mm |
8 | Nail plug @ 500 mm Ceiling anchor for fire protection @ 500 mm |
9 | Mineral wool |
Skim coat SATEN / FUGA&FINISH Light |
Section
CAD Details
Det. H01 Connection to massive element, horizontal section
Det. H02 Joint, horizontal section
Det. H03 Т-intersection, horizontal section
Det. H04.1 Corner intersection W1-1 with W1-1, horizontal section
Det. H04.2 Corner intersection W1-1 with W1-2, horizontal section
Det. H04.3 Corner intersection W1-1 with W1-3, horizontal section
Det. H05 Expansion gap, horizontal section
Det. H06 Transition between walls with different thickness, horizontal section
Det. H07 Connection to massive element, horizontal section
Det. H08.1 Connection W1-1 with L0-1, horizontal section
Det. H08.2 Connection W1-1 with L1-1, horizontal section
Det. H09 Connection W1-1 with W2-1, horizontal section
Det. H10 Т-intersection with shaft wall, horizontal section
Det. H11 Opening forming with UA profile, horizontal section
Det. H12 Electrical outlet, horizontal section
Det. V01 Upper connection to massive element, vertical section
Det. V02 Joint, vertical section
Det. V03.1 Lower connection to massive floor, vertical section
Det. V03.2 Lower connection to flooring system, vertical section
Det. H04 Upper connection with flooring system, vertical section
Documents
Technical catalogue
Linked Products
Linked Systems
Linked Articles
12.05.2021
How to Cut a Window Opening in a Partition Wall?
Today we explain how you can easily and quickly cut a window opening in plasterboard partition wall.
07.07.2021
How to Build a Double-Layer Partition Wall Technogips Pro W1-2 with Titan Board?
In the following article we give you detailed guidance about how to quickly and easily build a partition wall with Titan Board.