Technogips Pro S1-2
Certified system solutions. Guaranteed results.
Shaft wall with a stud construction with CW/UW profiles and a lining of two layers of gypsum plasterboard.
Characteristics
Class of Fire Resistance | up to EI 60 |
Shaft Wall Self-Weight | up to 31 kg/m² |
Shaft Wall Thickness | 75 | 100 | 125 | 150 | 175 mm |
Shaft Wall Heights | up to 9.50 m |
Optimal moisture protection when done with:
- Gypsum plasterboard Type Н2;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board DFH1IR;
- Blue Board Type GM DFH1IR;
Optimal fire protection when done with:
- Gypsum plasterboard Type DF;
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High level of airborne sound insulation when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High impact resistance and exceptional strength when done with:
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
System components
1 | Board Technogips Pro Type A / H2 / DF / DFH2 / Sound Comfort Extra DFIR / Titan Board / Blue Board |
2 | Premium Profile CW 50, 75, 100, 125, 150 / 0.6 mm |
3 | Premium Profile UW 50, 75, 100, 125, 150 / 0.6 mm |
4 | Acoustic foam tape @ the peripheral profiles |
5 | Joint tape @ all last layers joints + peripheral ones |
6 |
Joint filler FUGA&FINISH Light / FUGA FUGA for fire protection @ all layers |
7.1 | Drywall screw 3.5 x 25 mm @ 500 mm |
7.2 | Drywall screw 3.5 x 35/45 mm @ 250 mm |
8 | Nail plug @ 500 mm Ceiling anchor for fire protection @ 500 mm |
9 | Mineral wool |
Skim coat SATEN / FUGA&FINISH Light |
Section
![Section](https://www.technogipspro.com/attachments/AddableBlock/70/gallery/Section-S1-2_fit-detail.png)