Technogips Pro L1-1
Certified system solutions. Guaranteed results.
Interior wall lining with a single metal stud frame with CD profiles and single-layer cladding of gypsum plasterboard.
Characteristics
| Wall Lining Self-Weight | up to 16 kg/m² |
| Wall Lining Thickness | 44.5 ÷ 344.5 mm |
| Wall Lining Heights | up to 10.00 m |
Optimal moisture protection when done with:
- Gypsum plasterboard Type Н2;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board DFH1IR;
- Blue Board Type GMFH1IR;
Optimal fire protection when done with:
- Gypsum plasterboard Type DF;
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GMFH1IR;
High level of airborne sound insulation when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High impact resistance and exceptional strength when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
System components
| 1 | Board Technogips Pro Type A / H2 / DF / DFH2 / Sound Comfort Extra DFIR / Titan Board / Blue Board |
| 2 | Premium Profile Z140 CD 60 0.6 mm |
| 3 | Premium Profile Z140 UD 27 0.6 mm |
| 4 | Acoustic foam tape @ the peripheral profiles |
| 5.1 | Joint tape @ all inner joints |
| 5.2 | Separation Strip TrennFix @ all peripheral joints |
| 6 | Joint filler FUGA&FINISH Light / FUGA @ all layers |
| 7.1 | Drywall screw 3.5 x 25 mm @ 250 mm |
| 7.5 | Self-drilling Screw TEX LB 4.2 x 13 mm |
| 8.1 | Nail plug @ 500 mm Ceiling anchor for fire protection @ 500 mm |
| 8.2 | Cavity Dowel / Ceiling Anchor @ 1000 mm |
| 9 | Adjusting Bracket (load-bearing capacity 0.40 kN) @ 1500 mm max distance |
| 10 | Mineral wool Technogips Pro |
| 11 | Skim coat SATEN / FUGA&FINISH Light |
Section
CAD Details
Det. H01 Joint, horizontal section
Det. H02 Expansion gap, horizontal section
Det. H03.1a Outer corner, horizontal section
Det. H03.1b Outer corner with dry plaster, horizontal section
Det. H03.2 Internal corner, horizontal section
Det. V01 Upper connection to massive element, vertical section
Det. V02 Joint, vertical section
Det. V03 Lower connection to massive floor, vertical section
Documents
Green Book
Linked Products
Linked Systems
Linked Articles
24.02.2021
How to Build a Wall Niche?
In this blog article give you information on how you can build a wall niche in a wall lining from UA profiles.
25.08.2021
How to Build a Wall Lining for a Curved Wall?
Read this article if you want to learn how to mount a single-layer cladding on a suspended ceiling.