Interior partition wall made of double metal stud frame and two-sided double layer cladding of gypsum plasterboard.
Characteristics
Class of Fire Resistance | up to EI 120 |
Airborne Sound Insulation Rw | up to 63 dB |
Wall Self-Weight | up to 64 kg/m² |
Wall Thickness | 155 ÷ 800 mm |
Wall Heights | up to 7.20 m |
Optimal moisture protection when done with:
- Gypsum plasterboard Type Н2;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board DFH1IR;
- Blue Board Type GM DFH1IR;
Optimal fire protection when done with:
- Gypsum plasterboard Type DF;
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High level of airborne sound insulation when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High impact resistance and exceptional strength when done with:
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
System components
1 | Board Technogips Pro Type A / H2 / DF / DFH2 / Sound Comfort Extra DFIR / Titan Board / Blue Board |
2 | Premium Profile CW 50, 75, 100, 125, 150 / 0.6 mm |
3 | Premium Profile UW 50, 75, 100, 125, 150 / 0.6 mm |
4 | Acoustic foam tape @ the peripheral profiles |
5 | Joint tape @ all last layers joints + peripheral ones |
6 |
Joint filler FUGA&FINISH Light / FUGA FUGA for fire protection @ all layers |
7.1 | Drywall screw 3.5 x 25 mm @ 500 mm |
7.2 | Drywall screw 3.5 x 35/45 mm @ 250 mm for 12.5/15 mm boards |
8 | Nail plug @ 500 mm Ceiling anchor for fire protection @ 500 mm |
9 | Mineral wool |
Skim coat SATEN / FUGA&FINISH Light |
Section
CAD Details
Det. H01 Connection to massive element, horizontal section
Det. H02 Joint, horizontal section
Det. H03 Т-intersection W2-2B with W1-2, horizontal section
Det. H04.1 Corner intersection W2-2B with W2-2B, horizontal section
Det. H04.2 Connection W2-2B with W1-2, horizontal section
Det. H09 Connection W2-2B with W1-2, horizontal section
Det. H11 Opening forming with UA profile, horizontal section
Det. V01 Upper connection to massive element, vertical section
Det. V02 Joint, vertical section
Det. V03 Lower connection to massive floor, vertical section
Documents
Technical catalogue
Linked Products
Linked Systems
Linked Articles
19.08.2020
How to Install a Socket Box in Drywall?
Here you can find explanation on how to install a triple socket box and TV&LAN network socket box in a drywall.
06.04.2021
HOW TO: Tips for working with Premium profiles UA, construct a door opening, install a water heater in a wall lining
Here you can find out how and for what you can use Premium profiles UA .