Shaft wall with a stud construction with CW/UW profiles and a lining of three layers of gypsum plasterboard.
Characteristics
| Class of Fire Resistance | up to EI 90 |
| Shaft Wall Self-Weight | up to 44 kg/m² |
| Shaft Wall Thickness | 95 | 120 | 145 | 170 | 195 mm |
| Shaft Wall Heights | up to 9.90 m |
Optimal moisture protection when done with:
- Gypsum plasterboard Type Н2;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board DFH1IR;
- Blue Board Type GM DFH1IR;
Optimal fire protection when done with:
- Gypsum plasterboard Type DF;
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Type DFH2;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High level of airborne sound insulation when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
High impact resistance and exceptional strength when done with:
- Gypsum plasterboard Sound Comfort Extra DFIR;
- Gypsum plasterboard Titan Board Type DFH1IR;
- Blue Board Type GM DFH1IR;
System components
| 1 | Board Technogips Pro Type A / H2 / DF / DFH2 / Sound Comfort Extra DFIR / Titan Board / Blue Board |
| 2 | Premium Profile Z140 CW 0.6 mm |
| 3 | Premium Profile Z140 UW 0.6 mm |
| 4 | Acoustic foam tape @ the peripheral profiles |
| 5.1 | Joint tape @ all inner joints |
| 5.2 | Separation Strip TrennFix @ all peripheral joints |
| 6 |
Joint filler FUGA&FINISH Light / FUGA FUGA for fire protection @ all layers |
| 7.1 | Drywall screw 3.5 x 25 mm @ 500 mm |
| 7.2 | Drywall screw 3.5 x 35/45 mm @ 500 mm for 12.5/15 mm boards |
| 7.4 | Drywall screw 3.5 x 55/4.2 x 70 mm @ 250 mm for 12.5/15 mm boards |
| 8 | Nail plug @ 500 mm Ceiling anchor @ 500 mm |
| 9 | Mineral wool Technogips Pro |
| 10 | Skim coat SATEN / FUGA&FINISH Light |
Section
CAD Details
Det. H01 Connection to massive element, horizontal section
Det. H02 Joint, horizontal section
Det. H03 T-intersection with partition wall, horizontal section
Det. V01 Upper connection to massive element, vertical section
Det. V02 Joint, vertical section
Det. V03 Lower connection to massive floor, vertical section
Documents
Green Book
Linked Products
Linked Systems
Linked Articles
24.02.2021
How to Build a Wall Niche?
In this blog article give you information on how you can build a wall niche in a wall lining from UA profiles.
06.04.2021
HOW TO: Tips for working with Premium profiles UA, construct a door opening, install a water heater in a wall lining
Here you can find out how and for what you can use Premium profiles UA .